MAXIMUM WORKING PRESSURE:
350 /700 Bar
METER MAXIMUM FLOW RATE:
22.7 Kg/ minute
ELECTRICAL COMPONENTS:
Class 1 , Group B, C, D, Division 1 & Division
2 (with air purge enclosure) or to CENELEC Zone
1 & Zone 2 as required
2 (with air purge enclosure) or to CENELEC Zone
1 & Zone 2 as required
ELECTRICAL REQUIREMENTS:
240V 50 Hz or customised
DIMENSIONS 0/V* D* H):
860 mm x 560 mm x 2100 mm, Weight (Single hose
approx. 430 Lb.)
- High profile gasoline type dispenser cabinet, with high hose outlet
- Electrical components are approved for Class 1 , Group B, C, D, Division 1 , Hazardous Locations
- 4 air purged enclosure integrated to dispenser cabinet for Division 2 components (external air supply required)
- Nozzle holster with storage receptacle for Sherex hydrogen nozzle
- 3/8 "stainless piping and fittings on pressure lines
- Inlet valves and sequencing inlet valves are pneumatically operated ball valves (external air supply required).
- Ball valves are three-piece assemblies for convenient maintenance.
- Ball valves are operated with low-pressure air or nitrogen.
- Electronic computer for sale, volume with 1 "high, price per unit display is 0. 7" high. All displays are backlight display
- Twin Line delivery hose
- Breakaway system with release cage for pressure line on the hose.
- Large capacity filters on inlet line, with the coalescing element to remove oil, water, and particulate.
- Small to medium scale
- Gaseous Oxygen & Nitrogen Production
- Capacities – 50 m3 – 300 m3
- Low Power Consumption
- Easy to Operate
- Automatic Plants
- Plants made with high quality steel
- Less Maintenace